Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques.

Fecha de publicación: Fecha Ahead of Print:

Autores de IBSAL

  • Javier Montero Martín

    Autor

  • Alberto Albaladejo Martínez

    Autor

Autores ajenos a IBSAL

  • Oyagüe RC
  • Sánchez-Turrión A
  • López-Lozano JF
  • Suárez-García MJ

Abstract

This study evaluated the vertical discrepancy of implant-fixed 3-unit structures. Frameworks were constructed with laser-sintered Co-Cr, and vacuum-cast Co-Cr, Ni-Cr-Ti, and Pd-Au. Samples of each alloy group were randomly luted in standard fashion using resin-modified glass-ionomer, self-adhesive, and acrylic/urethane-based cements (n = 12 each). Discrepancies were SEM analyzed. Three-way ANOVA and Student-Newman-Keuls tests were run (P < 0.05). Laser-sintered structures achieved the best fit per cement tested. Within each alloy group, resin-modified glass-ionomer and acrylic/urethane-based cements produced comparably lower discrepancies than the self-adhesive agent. The abutment position did not yield significant differences. All misfit values could be considered clinically acceptable.

Datos de la publicación

ISSN/ISSNe:
1618-1247, 1618-1255

Odontology  SPRINGER

Tipo:
Article
Páginas:
249-253