Standardized flow cytometry for highly sensitive MRD measurements in B-cell acute lymphoblastic leukemia

Fecha de publicación: Fecha Ahead of Print:

Autores de IBSAL

Autores ajenos a IBSAL

  • Theunissen P
  • Mejstrikova E
  • Sedek L
  • van der Sluijs-Gelling AJ
  • Gaipa G
  • Bartels M
  • Sobral da Costa E
  • Kotrova M
  • Novakova M
  • Sonneveld E
  • Buracchi C
  • Bonaccorso P
  • Oliviera E
  • Te Marvelde JG
  • Szczepanski T
  • Lhermitte L
  • Hrusak O
  • Grigore GE
  • Fronkova E
  • Trka J
  • Brüggemann M
  • van Dongen JJ
  • van der Velden VH

Grupos

Abstract

A fully-standardized EuroFlow 8-color antibody panel and laboratory procedure was stepwise designed to measure minimal residual disease (MRD) in B-cell precursor (BCP) acute lymphoblastic leukemia (ALL) patients with a sensitivity of <= 10(-25), comparable to real-time quantitative polymerase chain reaction (RQ-PCR)-based MRD detection via antigen-receptor rearrangements. Leukocyte markers and the corresponding antibodies and fluorochromes were selected based on their contribution in separating BCP-ALL cells from normal/regenerating BCP cells in multidimensional principal component analyses. After 5 multicenter design-test-evaluate-redesign phases with a total of 319 BCP-ALL patients at diagnosis, two 8-color antibody tubes were selected, which allowed separation between normal and malignant BCP cells in 99% of studied patients. These 2 tubes were tested with a new erythrocyte bulk-lysis protocol allowing acquisition of high cell numbers in 377 bone marrow follow-up samples of 178 BCP-ALL patients. Comparison with RQ-PCR-based MRD data showed a clear positive relation between the percentage concordant cases and the number of cells acquired. For those samples with > 4 million cells acquired, concordant results were obtained in 93% of samples. Most discordances were clarified upon high-throughput sequencing of antigen-receptor rearrangements and blind multicenter reanalysis of flow cytometric data, resulting in an unprecedented concordance of 98% (97% for samples withMRD < 0.01%). In conclusion, the fully standardized EuroFlow BCP-ALLMRD strategy is applicable in > 98% of patients with sensitivities at least similar toRQ-PCR (<= 10(-25)), if sufficient cells (> 4310 6, preferablymore) are evaluated.

Datos de la publicación

ISSN/ISSNe:
0006-4971, 1528-0020

BLOOD  ELSEVIER

Tipo:
Article
Páginas:
347-357
PubMed:
27903527

Citas Recibidas en Web of Science: 23

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • MINIMAL RESIDUAL DISEASE; TIME QUANTITATIVE PCR; IG/TCR GENE REARRANGEMENTS; PROGNOSTIC-SIGNIFICANCE; BONE-MARROW; MONOCLONAL-ANTIBODY; CHILDHOOD; EXPRESSION; TARGETS; IMMUNOGLOBULIN

Cita

Compartir