Procedural and Short-Term Results With the New Watchman FLX Left Atrial Appendage Occlusion Device

Fecha de publicación:

Autores de IBSAL

Autores ajenos a IBSAL

  • Korsholm, Kasper
  • Thambo, Jean Benoit
  • Mazzone, Patrizio
  • Rioufol, Gilles
  • Grygier, Marek
  • Mobius-Winkler, Sven
  • Betts, Timothy
  • Meincke, Felix
  • Sandri, Marcus
  • Schmidt, Boris
  • Schmitz, Thomas
  • Nielsen-Kudsk, Jens Erik

Grupos

Abstract

OBJECTIVES This study sought to report early experience with the new-generation Watchman FLX device (Boston Scientific, Marlborough, Massachusetts). BACKGROUND The new-generation Watchman FLX features a reduced height, improved anchoring and fabric coverage, and a closed distal end. These design modifications aim to simplify implantation, allow full recapture and repositioning, and reduce peridevice leak and device-related thrombosis. METHODS A total of 165 patients undergoing left atrial appendage (LAA) occlusion (LAAO) with Watchman FLX were enrolled in a prospective, multicenter registry at 12 centers participating in the European limited market release program. RESULTS Mean age was 75.4 +/- 8.9 years, and CHA(2)DS(2)-VASc score 4.4 +/- 1.4. A total of 128 patients (77.6%) had a history of major bleeding, including previous intracranial hemorrhage in 55 cases (33.3%). LAA landing zone minimal and maximal mean diameters were 19.1 +/- 3.6 mm and 22.3 +/- 3.7 mm, and 24.2% of LAA were considered complex by dimensions. Technical success was achieved in all patients. Successful implantation at first attempt was achieved in 129 cases (78.2%), and a second device was required in 6 cases (3.6%). Procedure-related complications occurred in 3 patients (1.8%): 2 access-related (1.2%) and 1 pericardial effusion (0.6%). No peri-procedural strokes, deaths, or device embolizations occurred. Forty-nine patients (29.7%) were discharged with single antiplatelet therapy, 105 (63.6%) on dual antiplatelet, and 11 (6.7%) on anticoagulation. Imaging follow-up displayed just 1 peridevice leak >= 5 mm and 7 cases of device-related thrombosis (4.7%). During a median follow-up of 55 days (interquartile range: 45 to 148 days), there were 6 hemorrhagic complications (4.8%), 1 patient (0.8%) had an ischemic stroke, and 1 (0.8%) died. No late device embolizations occurred. CONCLUSIONS LAAO with the Watchman FLX is safe and effective in a wide range of LAA morphologies, with a low procedural complication rate, high degree of LAA sealing, and favorable short-term efficacy. (C) 2020 by the American College of Cardiology Foundation.

Datos de la publicación

ISSN/ISSNe:
1936-8798, 1876-7605

JACC-Cardiovascular Interventions  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
2732-2741
PubMed:
33189641

Citas Recibidas en Web of Science: 20

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • bleeding; left atrial appendage occlusion; novel devices; periprocedural complications; thromboembolic events