Safety and feasibility of peri-device leakage closure after LAAO: an international, multicentre collaborative study

Fecha de publicación:

Autores de IBSAL

Autores ajenos a IBSAL

  • Piayda, K
  • Sievert, K
  • Della Rocca, DG
  • Adeola, OG
  • Alkhouli, M
  • Yoo, D
  • Benito-Gonzalez, T
  • Galea, R
  • Skurk, C
  • De Backer, O
  • Nielsen-Kudsk, JE
  • Grygier, M
  • Beaty, EH
  • Newton, J
  • De Prado, AP
  • Raber, L
  • Gibson, D
  • Van Niekerk, C
  • Ellis, CR
  • Horton, RP
  • Natale, A
  • Grundwald, I
  • Zeus, T
  • Sievert, H

Grupos

Abstract

Background: Residual peri-device leakage (PDL) is frequent after left atrial appendage occlusion (LAAO). Little is known about management strategies, procedural aspects and outcomes of interventional PDL closure. Aims: The aim of this study was to assess the safety and feasibility of PDL closure after LAAO. Methods: Fifteen centres contributed data on baseline characteristics, in-hospital and follow-up outcomes of patients who underwent PDL closure after LAAO. Outcomes of interest included acute success and complication rates and long-term efficacy of the procedure. Results: A total of 95 patients were included and a cumulative number of 104 leaks were closed. The majority of PDLs were detected within 90 days (range 41-231). Detachable coils were the most frequent approach (42.3%), followed by the use of the AMPLATZER Vascular Plug II (29.8%) and the AMPLATZER Duct Occluder II (17.3%). Technical success was 100% with 94.2% of devices placed successfully within the first attempt. There were no major complications requiring surgical or transcatheter interventions. During follow-up (96 days [range 49-526]), persistent leaks were found in 18 patients (18.9%), yielding a functional success rate of 82.7%, although PDLs were significantly reduced in size (pre-leak size(max): 6.1 +/- 3.6 mm vs post-leak size(max): 2.5 +/- 1.3 mm, p<0.001). None of the patients had a leak >5 mm. Major adverse events during follow-up occurred in 5 patients (2 ischaemic strokes, 2 intracranial haemorrhages, and 1 major gastrointestinal bleeding). Conclusions: Several interventional techniques have become available to achieve PDL closure. They are associated with high technical and functional success and low complication rates.

Datos de la publicación

ISSN/ISSNe:
1774-024X, 1969-6213

EuroIntervention  EUROPA EDITION

Tipo:
Article
Páginas:
1033-
PubMed:
34219662

Citas Recibidas en Web of Science: 14

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • atrial fibrillation; LAA closure; stroke

Campos de Estudio

Cita

Compartir