Transcatheter aortic valve implantation in patients with extra- small aortic annuli

Fecha de publicación:

Autores de IBSAL

Autores ajenos a IBSAL

  • Tirado-Conte, Gabriela
  • Rodes-Cabau, Josep
  • Oteo, Juan F.
  • Pan, Manuel
  • Munoz, Erika
  • Witberg, Guy
  • Cheema, Asim
  • Alpieri, Alberto
  • Lopez, Diego
  • Amat-Santos, Ignacio
  • Akodad, Mariama
  • Ojeda, Soledad
  • Serra, Vicenc
  • Garcia-Blas, Sergio
  • Alfonso, Fernando
  • De Backer, Ole
  • Asmarats, Luis
  • Munoz, Antonio
  • Hamdan, Ashraf
  • Toggweiler, Stefan
  • del Valle, Raquel
  • Salido, Luisa
  • Estevez-Loureiro, Rodrigo
  • Alfaro, Luis Enrique Martin
  • Gheorghe, Livia
  • Dabrowski, Maciec
  • Berenguer, Alberto
  • Saia, Francesco
  • Webb, John
  • Sondergaard, Lars

Grupos

Abstract

Background: A small aortic annulus (SAA) is a risk factor for prosthesis-patient mismatch (PPM) in patients undergoing surgical or transcatheter aortic valve implantation (TAVI). Data regarding TAVI in patients with extra-SAA are scarce. Aims: The aim of this study was to analyse the safety and efficacy of TAVI in patients with extra-SAA. Methods: A multicentre registry study including patients with extra-SAA (defined as an aortic annulus area <280 mm2 and/or perimeter <60 mm) undergoing TAVI was established. Primary efficacy and safety end-points were defined as device success and early safety at 30 days, respectively, using the Valve Academic Research Consortium-3 criteria, and were analysed according to valve type: self-expanding (SEV) versus balloon-expandable (BEV). Results: A total of 150 patients were included, of which 139 (92.7%) were women, and 110 (73.3%) received an SEV. Intraprocedural technical success was 91.3%, with a higher rate in patients receiving an SEV (96.4% vs 77.5% with BEV; p=0.001). Overall, 30-day device success was 81.3%, (85.5% with SEV vs 70.0% with BEV; p=0.032). The primary safety endpoint occurred in 72.0% of patients (with no dif-ference between groups; p=0.118). Severe PPM occurred in 12% (9.0% with SEV and 24.0% with BEV; p=0.039), with no impact on all-cause mortality, cardiovascular mortality, or heart failure readmission at 2-year follow-up. Conclusions: TAVI is a safe and feasible treatment in patients with extra-SAA with a high rate of technical success. The use of SEV was associated with a lower rate of intraprocedural complications, higher device success at 30 days and better haemodynamic outcomes compared to BEV.

Datos de la publicación

ISSN/ISSNe:
1774-024X, 1969-6213

EuroIntervention  EUROPA EDITION

Tipo:
Article
Páginas:
340-340
PubMed:
37334654

Citas Recibidas en Web of Science: 7

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • degenerative valve; elderly (> 75 years); TAVI

Campos de Estudio

Cita

Compartir