Impact of Device Implant Depth After Left Atrial Appendage Occlusion
Autores de IBSAL
Autores ajenos a IBSAL
- Cepas-Guillén, P
- Flores-Umanzor, E
- Leduc, N
- Bajoras, V
- Perrin, N
- Farjat-Pasos, J
- McInerney, A
- Lafond, A
- Millán, X
- Zendjebil, S
- O'Hara, G
- Ibrahim, R
- de Backer, O
- Arzamendi, D
- Sanchis, L
- Garot, P
- Nielsen-Kudsk, JE
- Aminian, A
- Rodés-Cabau, J
- Freixa, X
Grupos
Abstract
BACKGROUND Device-related thrombus (DRT) remains one of the main concerns after left atrial appendage occlusion (LAAO). Several risk factors have been proposed, but most cannot be modulated. A modifiable factor such as device implantation depth is a potential target to adjust the risk for DRT.OBJECTIVES The aim of this study was to assess the impact of LAAO device implantation depth as a predisposing factor for DRT.METHODS The study included patients who underwent successful LAAO at 9 centers in Europe and Canada. Patients were classified into 2 groups: proximal device implantation (covered pulmonary ridge [PR] in the lobe and disc cohort or <5 mm from the PR in the single-lobe cohort) and distal device implantation (uncovered PR in the disc and lobe cohort and >= 5 mm in the single-lobe cohort).RESULTS A total of 1,317 patients were included. Among these, proximal and distal device implantation was achieved in 732 (55%) and 585 (45%) patients, respectively. No differences in procedural outcomes were observed between the groups. At follow-up, patients with proximal implantation had a lower incidence of DRT (2.3%) than those with distal implantation (12.2%) (P < 0.001). Deeper device implantation and a larger uncovered left atrial appendage area were associated with a higher incidence of DRT (P < 0.001), regardless of device type. In multivariable analysis, distal implant (HR: 5.92; 95% CI: 3.39-10.36) and no or single antiplatelet therapy (HR: 1.62; 95% CI: 0.99-2.62) emerged as independent predictors of DRT.CONCLUSIONS LAAO device implantation depth is an independent risk factor for DRT. Deeper device implantation and larger uncovered left atrial appendage areas were associated with a higher incidence of DRT.
Datos de la publicación
- ISSN/ISSNe:
- 1936-8798, 1876-7605
- Tipo:
- Article
- Páginas:
- 2139-2149
- PubMed:
- 37565966
JACC-Cardiovascular Interventions ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 42
Documentos
- No hay documentos
Filiaciones
Keywords
- atrial fibrillation; device-related thrombus; left atrial appendage occlusion; stroke
Campos de Estudio
Cita
Cepas P, Flores E, Leduc N, Bajoras V, Perrin N, Farjat J, McInerney A, Lafond A, Millán X, Zendjebil S, O'Hara G, Ibrahim R, de Backer O, Cruz I, Arzamendi D, Sanchis L, Garot P, Nielsen JE, Nombela L, Aminian A, Rodés J, Freixa X. Impact of Device Implant Depth After Left Atrial Appendage Occlusion, JACC-Cardiovascular Interventions. 2023; 16(17): p. 2139-2149. FI: 11,700(Q1) (D1)
Portal de investigación