Left Atrial Appendage Occlusion Under Miniaturized Transesophageal Echocardiographic Guidance and Conscious Sedation Multicenter European Experience

Fecha de publicación: Fecha Ahead of Print:

Autores de IBSAL

Autores ajenos a IBSAL

  • Aminian, A
  • Leduc, N
  • Freixa, X
  • Swaans, MJ
  • Ben Yedder, M
  • Maarse, M
  • Sanchis, L
  • Cepas-Guillen, P
  • Eschalier, R
  • Boersma, LVA

Grupos

Abstract

BACKGROUND Left atrial appendage occlusion (LAAO) procedures are widely guided by standard transesophageal echocardiography (TEE) probes, requiring general anesthesia in most patients. The use of miniaturized TEE probes allows for LAAO guidance under local anesthesia and offers an attractive imaging alternative to standard TEE probes.OBJECTIVES The aim of this study was to assess the safety and efficacy of miniaturized TEE probes for procedural guidance of LAAO.METHODS Multicenter retrospective observational study of LAAO procedures performed under miniaturized TEE guidance and conscious sedation. The primary efficacy endpoint was technical success. The secondary efficacy endpoint was procedural success (technical success without major periprocedural complications). The safety outcome was a composite of major periprocedural complications.RESULTS A total of 546 consecutive LAAO procedures were performed in 5 European centers. Technical success was achieved in 534 (98.0%) patients. Sixteen major periprocedural complications occurred in 15 (2.9%) patients, yielding a procedural success rate of 97.0%. Conversion to general anesthesia was required in 4 (0.7%) patients. Short-term imaging follow-up was available in 422 patients with an incidence of major (>5 mm) TEE-detected residual leaks of 0.7%, complete LAA occlusion of 82.2% on cardiac computed tomography, and device-related thrombus of 5%. As compared with procedural 2-dimensional imaging for device sizing, preprocedural assessment by 3-dimensional imaging resulted in improved technical success (100% vs 95.0%; P < 0.001).CONCLUSIONS LAAO under conscious sedation and miniaturized TEE guidance is safe and feasible with a high rate of technical success and a low rate of periprocedural complications. (J Am Coll Cardiol Intv 2023;16:1889-1898)(c) 2023 by the American College of Cardiology Foundation.

Datos de la publicación

ISSN/ISSNe:
1936-8798, 1876-7605

JACC-Cardiovascular Interventions  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
1889-1898
PubMed:
37587597

Citas Recibidas en Web of Science: 21

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • atrial fibrillation; left atrial appendage; left atrial appendage occlusion; miniaturized transesophageal echocardiography; stroke prevention

Campos de Estudio

Cita

Compartir