The EuroFlow PIDOT external quality assurance scheme: enhancing laboratory performance evaluation in immunophenotyping of rare lymphoid immunodeficiencies

Fecha de publicación: Fecha Ahead of Print:

Autores de IBSAL

Autores ajenos a IBSAL

  • Neirinck, J
  • Buysse, M
  • Brdickova, N
  • De Vriendt, C
  • Kerre, T
  • Haerynck, F
  • Bossuyt, X
  • van Dongen, JJM
  • Hofmans, M
  • Bonroy, C
  • Kalina, T
  • EuroFlow PID Consortium

Grupos

Abstract

Objectives The development of External Quality Assessment Schemes (EQAS) for clinical flow cytometry (FCM) is challenging in the context of rare (immunological) diseases. Here, we introduce a novel EQAS monitoring the primary immunodeficiency Orientation Tube (PIDOT), developed by EuroFlow, in both a 'wet' and 'dry' format. This EQAS provides feedback on the quality of individual laboratories (i.e., accuracy, reproducibility and result interpretation), while eliminating the need for sample distribution.Methods In the wet format, marker staining intensities (MedFIs) within landmark cell populations in PIDOT analysis performed on locally collected healthy control (HC) samples, were compared to EQAS targets. In the dry format, participants analyzed centrally distributed PIDOT flow cytometry data (n=10).Results We report the results of six EQAS rounds across 20 laboratories in 11 countries. The wet format (212 HC samples) demonstrated consistent technical performance among laboratories (median %rCV on MedFIs=34.5 %; average failure rate 17.3 %) and showed improvement upon repeated participation. The dry format demonstrated effective proficiency of participants in cell count enumeration (range %rCVs 3.1-7.1 % for the major lymphoid subsets), and in identifying lymphoid abnormalities (79.3 % alignment with reference).Conclusions The PIDOT-EQAS allows laboratories, adhering to the standardized EuroFlow approach, to monitor interlaboratory variations without the need for sample distribution, and provides them educational support to recognize rare clinically relevant immunophenotypic patterns of primary immunodeficiencies (PID). This EQAS contributes to quality improvement of PID diagnostics and can serve as an example for future flow cytometry EQAS in the context of rare diseases.

Datos de la publicación

ISSN/ISSNe:
1434-6621, 1437-4331

CLINICAL CHEMISTRY AND LABORATORY MEDICINE  WALTER DE GRUYTER GMBH

Tipo:
Article
Páginas:
621-635
PubMed:
39423371

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • external quality assurance; flow cytometry; EuroFlow; primary immunodeficiencies; standardization

Cita

Compartir