Transjugular Transcatheter Tricuspid Valve Replacement Early Compassionate Use Outcomes

Fecha de publicación: Fecha Ahead of Print:

Autores de IBSAL

Autores ajenos a IBSAL

  • Stolz, Lukas
  • Cheung, Anson
  • Boone, Robert
  • Fam, Neil
  • Ong, Geraldine
  • Villablanca, Pedro
  • Jabri, Ahmad
  • De Backer, Ole
  • Molller, Jacob Eifer
  • Tchetche, Didier
  • Oliva, Omar
  • So, Kent Chak-yu
  • Lam, Yat-yin
  • Latib, Azeem
  • Scotti, Andrea
  • Coisne, Augustin
  • Sudre, Arnaud
  • Dreyfus, Julien
  • Nejjari, Mohammed
  • Favre, Paul-Emile
  • Estevez-Loureiro, Rodrigo
  • Makkar, Raj
  • Patel, Dhairya
  • Leurent, Guillaume
  • Donal, Erwan
  • Modine, Thomas
  • Hausleiter, Joerg

Grupos

Abstract

BACKGROUND Data on procedural and early outcomes after transjugular transcatheter tricuspid valve replacement (TTVR) are limited. OBJECTIVES This study sought to evaluate first-in-man procedural and clinical outcomes after transjugular TTVR with a special focus on patients who received large device sizes in whom TTVR outcomes have been questioned. METHODS The retrospective registry included patients who underwent TTVR using the LuX-Valve Plus system (Jenscare Biotechnology Co Ltd) for symptomatic tricuspid regurgitation (TR) from January 2022 until February 2024 at 15 international centers in a compassionate use setting. The endpoints were procedural TR reduction, in-hospital death, adverse events, and 1-month survival. We further stratified results according to the size of the implanted device (<55 vs >= 55 mm). RESULTS The registry included a total of 76 patients at a median age of 78 years (Q1-Q3: 72-83 years, 47.4% women). TR was reduced to <= 2+ and <= 1+ in 94.7% and 90.8% of patients (75.0% of patients received TTVR devices >= 55 mm) with well-sustained results at 1-month follow-up (TR <= 2+ in 95.0% and <= 1+ 86.8%). Residual TR was paravalvular in all cases. In-hospital death occurred in 4 patients (5.3%). Four patients (5.3%) underwent cardiac surgery during index hospitalization. Major in-hospital bleeding events occurred in 5 patients (6.6%). New in-hospital pacemaker implantation was required in 3.9% of patients in the overall cohort (5.7% in "pacemaker-naive" individuals). No cases of valve thrombosis, stroke, myocardial infarction, or pulmonary embolism were observed. At 1-month follow-up, survival was 94.4%, and NYHA functional class significantly improved. One further patient received a pacemaker, 1 further bleeding event occurred, and 2 patients underwent reintervention or surgery within the first 30 days after TTVR. No differences in procedural outcomes or adverse events were observed after stratification for valve size. CONCLUSIONS Transjugular TTVR appears to be a safe and effective treatment option for patients with severe TR with comparable outcomes in very large tricuspid anatomies. (JACC Cardiovasc Interv. 2024;17:1936-1945) (c) 2024 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Datos de la publicación

ISSN/ISSNe:
1936-8798, 1876-7605

JACC-Cardiovascular Interventions  ELSEVIER SCIENCE INC

Tipo:
Article
Páginas:
1936-1945
PubMed:
39197992

Citas Recibidas en Web of Science: 31

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Campos de Estudio

Compartir