Early Hemodynamic Performance of the SAPIEN 3 Ultra Resilia and Evolut Valves: A Propensity-Matched Analysis
Autores de IBSAL
Autores ajenos a IBSAL
- Avvedimento, M
- Mas-Peiro, S
- Aktaa, S
- Nombela-Franco, L
- Alperi, A
- Franzone, A
- Campelo-Parada, F
- Urena, M
- Cepas-Guillén, P
- Tirado, G
- Avanzas, P
- Laffond, AE
- Esposito, G
- Tamir, M
- Suc, G
- Mohammadi, S
- Pibarot, P
- Côté, M
- Webb, JG
- Rodés-Cabau, J
Grupos
Abstract
Background: Limited data are available on early hemodynamic outcomes of the balloon-expandable SAPIEN 3 Ultra Resilia (S3UR) (Edwards Lifesciences, Irvine, CA) compared with the self-expandable Evolut (Medtronic, Minneapolis, MN) transcatheter heart valves. In this study we aimed to compare the hemodynamic performance of the S3UR with contemporary Evolut platforms (Evolut PRO, PRO+, FX) in a propensity-matched study. Methods: A total of 307 patients who received an S3UR valve were matched with 488 patients who received Evolut valves (mean age, 80.1 +/- 7 years; 46.2% women). The primary end point was valve hemodynamics (aortic mean gradient, effective orifice area [EOA], severe prosthesis-patient mismatch [PPM], and moderate to severe aortic regurgitation [AR]) at 1-3 months after transcatheter aortic valve replacement. Secondary end points included clinical outcomes. Results: Evolut valves were associated with lower mean gradients (8.0 +/- 3.1 mm Hg vs 9.8 +/- 3.8 mm Hg; P < 0.001) but higher rates of residual AR (mild AR, 10.7% vs 4.1%; moderate to severe AR, 4.2% vs 1.4%; P < 0.001). EOA values and PPM rates were comparable. In patients with small aortic annulus (< 430 mm(2)), Evolut valves showed larger EOA (1.94 +/- 0.3 cm(2) vs 1.83 +/- 0.4 cm(2); P = 0.038) and lower gradients (7.8 +/- 2.4 mmHg vs 10.9 +/- 4.5 mmHg; P < 0.010). Moderate to severe AR and PPM were similar between groups. Despite comparable device success, early safety outcomes favoured the S3UR (81.8% vs 60.5%; P < 0.010 for S3UR and Evolut, respectively), because of higher rates of pacemaker implantation, atrial fibrillation, major vascular complication, and type 2-3 bleeding in the Evolut cohort. Conclusions: Evolut valves showed lower transprosthetic gradients but a higher rate of residual AR compared with the S3UR. Further studies are needed to validate these findings and investigate their effect on long-term outcomes.
Datos de la publicación
- ISSN/ISSNe:
- 0828-282X, 1916-7075
- Tipo:
- Article
- Páginas:
- 2407-2416
- PubMed:
- 40812524
CANADIAN JOURNAL OF CARDIOLOGY ELSEVIER SCIENCE INC
Citas Recibidas en Web of Science: 3
Documentos
- No hay documentos
Filiaciones
Keywords
- Aortic stenosis; transcatheter heart valve; transcatheter aortic valve replacement; SAPIEN 3 Ultra Resilia; Evolut
Cita
Avvedimento M, Mas S, Aktaa S, Nombela L, Alperi A, Gonzalez IC, Franzone A, Campelo F, Urena M, Cepas P, Tirado G, Avanzas P, Laffond AE, Esposito G, Tamir M, Suc G, Mohammadi S, Pibarot P, Côté M, Webb JG, Rodés J. Early Hemodynamic Performance of the SAPIEN 3 Ultra Resilia and Evolut Valves: A Propensity-Matched Analysis, CANADIAN JOURNAL OF CARDIOLOGY. 2025; 41(12): p. 2407-2416. FI: 5,700(Q1) (D2)
Portal de investigación