Impact of double stent retriever configuration on first-pass effect in stroke: a multicenter study

Fecha de publicación:

Autores de IBSAL

Autores ajenos a IBSAL

  • Pérez-García, C
  • Lopez-Frías, A
  • Rosati, S
  • Lopez, JL
  • Venegas, J
  • González, E
  • Fondevila, J
  • de Rueda, ME
  • Zamarro, J
  • Baldi, S
  • Díaz, T
  • de la Rosa, C
  • Grajera, JC
  • Marco, FB
  • Cuba, V
  • Olmedo, JMM
  • Mendez, JC
  • Remollo, S
  • Bermejo, R
  • Morales, E
  • Gomez-Escalonilla, C
  • Moreu, M

Grupos

Abstract

Background Efficient recanalization of occluded cerebral arteries is crucial in the treatment of acute ischemic stroke. Double stent retrievers have shown the potential to enhance the rates of recanalization on the first pass. This study aims to evaluate the efficacy and safety of the double stent retriever technique and the predictors of achieving first-pass effect in patients with acute ischemic stroke.Methods This prospective multicenter study involved 209 patients from 16 comprehensive stroke centers in Spain. Patients with occlusions in the anterior circulation were treated using the Aperio Hybrid double stent retriever. The study examined various deployment techniques, including simultaneous and sequential deployment and stent configurations, comparing the Y-shaped and parallel configurations.Results The double stent retriever technique achieved a first-pass effect in 72.7% of cases and a final successful recanalization rate of 99.5%. The Y-shaped configuration was significantly associated with higher recanalization rates on the first pass (OR 2.59, 95% CI 1.18 to 5.68, P=0.02). Procedural complications were mild to moderate in 6.7% and severe in 1.5% of cases, with symptomatic intracranial hemorrhage occurring in 3.3% of patients. At 3 months follow-up, 57.2% of patients achieved a good clinical outcome, with a mortality rate of 15.1%.Conclusion The findings support the efficacy of the double stent retriever technique, particularly the Y-shaped configuration, in achieving high recanalization rates on the first pass with an acceptable safety profile. This technique may offer clinical benefits for future acute ischemic stroke treatment protocols.

Datos de la publicación

ISSN/ISSNe:
1759-8478, 1759-8486

Journal of NeuroInterventional Surgery  BMJ PUBLISHING GROUP

Tipo:
Article
Páginas:
1294-1300
PubMed:
39288975

Citas Recibidas en Web of Science: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Thrombectomy; Stroke; Stent; Artery; Device

Compartir