Development and Validation of the Bronchoscope Quality Questionnaire for Assessing Bronchoscopists' Perception of Single-Use Flexible Bronchoscope Quality
Autores de IBSAL
Autores ajenos a IBSAL
- Flandes, J
- Cerchiaro-Torrado, LV
- Disdier, C
- Alfayate, J
- Fernández-Navamuel, I
- Augustí, C
- Lucena, CM
- Martinez-Muñiz, F
- Pajares, V
- Andreo, F
- Centeno, C
- Montero, C
- Ariza, M
- Tuta-Quintero, E
- Gallego, R
- Torregó, A
- González, H
- Vega-Sanchez, BD
- García-López, JJ
- García-Gallo, CL
- Díaz-Agero, P
- Luque-Crespo, E
- Pavón-Masa, M
- Cases, E
- Robles, J
- Uribe-Hernández, AM
- Giraldo-Cadavid, LF
Grupos
Abstract
Introduction: The risk of cross-infections (including SARS-CoV-2) and damage to the flexible bronchoscope has led to the development of single-use flexible bronchoscopes as a cost-effective alternative. It is necessary for the bronchoscopist to evaluate the perception of the quality of these devices to determine if their quality is satisfactory for the user. The objective of this study was the construction and validation of a Bronchoscope Quality Questionnaire (BQQ) to evaluate the quality of the flexible bronchoscope perceived by the bronchoscopist. Methods: We conducted a cross-sectional study in 21 pulmonology centres in Spain. A first version of the BQQ was carried out by a group of experts, the construct validity was evaluated, and a factor analysis reduced the number of items. Feasibility of the BQQ was assessed by a questionnaire, internal consistency by the Cronbach's alpha coefficient, and intra- and interrater reliability by the intraclass correlation coefficient (ICC). Results: The final version of the BQQ was composed of six domains and 18 items. The median completion time was 5 min, and it was not difficult to understand the items. Cronbach's alpha was 0.89, the intrarater ICC was 0.70 (95% CI: 0.56-0.79), and the interrater ICC was 0.64 (95% CI: 0.47-0.76). Conclusion: The BQQ showed good feasibility, internal consistency, and intra- and interrater reliability, which makes it suitable for evaluating the quality of flexible bronchoscopes perceived by the bronchoscopist. Flexible bronchoscopes are thin, flexible tubes with a small camera at the tip that lung specialists use to examine the airways and perform procedures such as collecting fluid or tissue samples from the lungs. Recently, single-use (disposable) bronchoscopes have been introduced as an alternative to reusable ones. They offer several advantages, including reduced risk of infection and easier handling, but their quality needs to be evaluated by the specialists who use them. In this study, a team of lung doctors created and tested a questionnaire called the Bronchoscope Quality Questionnaire (BQQ). This questionnaire was designed to measure how well single-use bronchoscopes perform during common procedures, based on the opinion of the doctors using them. The questionnaire asks about important aspects such as image clarity, ease of use, and suction ability (how well the device can remove fluids or secretions). The study involved 300 procedures across 21 hospitals in Spain. Doctors completed the BQQ after each procedure. The results showed that the questionnaire is easy to complete, reliable, and consistent in how it measures different features of the bronchoscope. The final version of the BQQ includes 18 questions divided into six areas related to bronchoscope quality. The BQQ can help medical teams compare bronchoscopes and choose those that best meet their clinical needs. It may also support the safe and gradual introduction of single-use bronchoscopes in hospitals around the world.
Datos de la publicación
- ISSN/ISSNe:
- 0025-7931, 1423-0356
- Tipo:
- Article
- Páginas:
- 720-729
- DOI:
- 10.1159/000546088
- PubMed:
- 40300585
RESPIRATION KARGER
Documentos
- No hay documentos
Filiaciones
Keywords
- Bronchoscopy; Factor analysis; Psychometric properties; Quality; Questionnaire; Reliability